High quality parts, key parts are imported;
Remote monitoring (optional);
Multi-layer pipe measurement (optional) ;
Measurement power consumption is low (<30W);
0.001mm The highest measurement accuracy is 0.001mm;
The OD measurement range is 10~1600mm;
The wall thickness measuring range is 0.25~127mm;
Reduce and eliminate the quality risk of plastic pipe production and improve product quality;
Shorten startup time and reduce product rejection rate;
Complete production data record and archive function, each pipe quality report (optional);
Automatic numbering of pipes, automatic identification and marking of unqualified pipes.
Model | Configuration | OD Measuring Dange (mm) | Wall thickness measuring range (mm) |
ULTRAMAC 032-4T | 4 | 10-32 | 0.25-6 |
ULTRAMAC 063-4T | 4 | 16-63 | 0.25-6 |
ULTRAMAC 063-4T/2 | 4 | 16-63 | 0.25-6 |
ULTRAMAC 125-4T | 4 | 20-125 | 0.5-12.7 |
ULTRAMAC 160-4T | 4 | 32-160 | 1.27-20 |
ULTRAMAC 160-8T | 8 | 32-160 | 1.27-20 |
ULTRAMAC 250-4T | 4 | 90-250 | 1.27-20 |
ULTRAMAC 250-8T | 8 | 90-250 | 1.27-20 |
ULTRAMAC 315-4T | 4 | 110-315 | 2.5-50.8 |
ULTRAMAC 315-8T | 8 | 110-315 | 2.5-50.8 |
ULTRAMAC 450-4T | 4 | 160-450 | 2.5-50.8 |
ULTRAMAC 450-8T | 8 | 160-450 | 2.5-50.8 |
ULTRAMAC 630-4T | 4 | 250-630 | 7.5-127 |
ULTRAMAC 630-8T | 8 | 250-630 | 7.5-127 |
ULTRAMAC 800-4T | 4 | 315-800 | 7.5-127 |
ULTRAMAC 800-8T | 8 | 315-800 | 7.5-127 |
ULTRAMAC 1000-8T | 8 | 560-1000 | 7.5-127 |
ULTRAMAC 1000-16T | 16 | 560-1000 | 7.5-127 |
ULTRAMAC 1200-8T | 8 | 800-1200 | 7.5-127 |
ULTRAMAC 1200-16T | 16 | 800-1200 | 7.5-127 |
ULTRAMAC 1600-8T | 8 | 800-1600 | 7.5-127 |
ULTRAMAC 1600-16T | 16 | 800-1600 | 7.5-127 |